M16 to M130 as standard.
Other parallel thread options available on request, including BSPP, PG, NPSM and ET. NPT available as 387 Exe Plug.
Metric entry threads are 1.5mm pitch as standard.
Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).
Increased Safety and Flameproof Exe I Mb, Exd I Mb, Exe IIC Gb, Exd IIC Gb, Extb IIIC Db, IM2 / II 2GD.
Certificate No's
Baseefa11ATEX0149X and IECEx BAS 11.0071X.
Suitable for use in:
Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.
Construction and Test Standards:
IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
Ingress Protection:
IP66.
Operating Temperature Range:
Nitrile ‘O’ Ring fitted as standard -60°C to +80°C.
Silicone Option -60°C to +160°C.
Group I, II and III.
487 STOPPING PLUGS SELECTION TABLE | |||
---|---|---|---|
Thread Size | Length of Thread | ‘S’ Dia. | Allen Key |
M16 | 15 | 24 | 6 |
M20 | 15 | 26.5 | 10 |
M25 | 15 | 34 | 10 |
M32 | 15 | 45 | 10 |
M40 | 15 | 51.5 | 10 |
M50 | 15 | 61.5 | 10 |
M63 | 15 | 74.5 | 10 |
M75 | 15 | 86.5 | 10 |
All dimensions in millimetres. |
Ordering Format [ Product / Thread Size / Material / Finish ]
Example: 487 / M32 / Brass / Nickel Plated
To close unused cable gland entries and maintain the integrity of the equipment.
387 Stopping Plugs are manufactured in Brass (standard), Nickel Plated Brass or 316 Stainless Steel..
Example: 387 / ?" NPT
Increased Safety Exe II 2 GD IP66
Certificate No's
Baseefa06ATEX0118U and IECEx BAS06.0029U
Construction and Test Standards:
IEC/EN 60079-0 and IEC/EN 60079-7.
Ingress Protection:
To meet with IP66 and IP67, the stopping plugs must be fitted perpendicular to the equipment face in a suitably sized threaded or plain hole and the equipment face must be smooth. Plain holes must be no larger than 0.7mm above the major diameter of the stopping plug thread and the plug must be held in place with a lock nut. A serrated washer may also be fitted.
Operating Temperature Range:
Nitrile ‘O’ Ring fitted as standard -60°C to +80°C.
Silicone Option -60°C to +160°C.
387 STOPPING PLUG SELECTION TABLE | ||
---|---|---|
Thread Size * | ‘S’ Dia. | Key Size (Across Flats) |
?" NPT | 30.0 | 8.0 |
?" NPT | 36.5 | 10.0 |
1" NPT | 44.0 | 10.0 |
1?" NPT | 56.0 | 10.0 |
1?" NPT | 62.0 | 19.0 |
2" NPT | 74.5 | 19.0 |
2?" NPT | 87.2 | 19.0 |
3" NPT | 104.0 | 19.0 |
All dimensions in millimetres (except * where dimensions are in inches). |
M16 to M75 as standard.
Other thread options available on request, including BSPP, PG, NPT, ET and NPSM.
Manufactured in Brass, Nickel Plated Brass, Aluminium, Steel, Nickel Plated Steel and Stainless Steel.
Increased Safety and Flameproof Exe IIC Gb, Exd IIC Gb, Extb IIIC Db, II 2GD.
Certificate No's
Baseefa11ATEX0150U and IECEx BAS 11.0072U.
Suitable for use in:
Zone 1, Zone 2, Zone 21 and Zone 22.
Construction and Test Standards:
IEC/EN 60079-0, IEC/EN 60079-1 IEC/EN 60079-7 and IEC/EN 60079-31.
Ingress Protection:
IP66.
Operating Temperature Range:
-60°C to +200°C.
Group I, II and III.
479 INLINE ADAPTOR SELECTION TABLE | ||||||
---|---|---|---|---|---|---|
Male Thread Size | Thread Pitch | Male Thread Size | Thread Pitch | Thread Length | Across Flats | Across Corners |
M16 | 1.5 | M16 | 1.5 | 15 | 24 | 26.5 |
M20 | 1.5 | M20 | 1.5 | 15 | 30 | 32.5 |
M25 | 1.5 | M25 | 1.5 | 15 | 36 | 39.5 |
M32 | 1.5 | M32 | 1.5 | 15 | 46 | 50.5 |
M40 | 1.5 | M40 | 1.5 | 15 | 55 | 60.6 |
M50 | 1.5 | M50 | 1.5 | 15 | 65 | 70.8 |
M63 | 1.5 | M63 | 1.5 | 15 | 80 | 88.0 |
M75 | 1.5 | M75 | 1.5 | 15 | 95 | 109.5 |
All dimensions in millimetres. Note: Different thread sizes and types are permitted at each end of the adaptor, a step of one thread size is permitted between the male threads. Where different thread types / sizes are supplied, the overall dimensions of the adaptor may differ from the ones in the table |
Ordering Format [ Product / Thread Size / Material / Finish ]
Example: 479 / M32 Male x 1?" NPT Male / Brass / Nickel Plated
Always state male thread first