免费观看理论片毛片-免费观看久久-免费观看黄a一级视频日本-免费观看黄a一级视频-91传媒视频-91吃瓜

粉體行業在線展覽

產品

產品>

粉體測試設備>

光譜檢測分析儀

>飛秒瞬態吸收/拉曼光譜儀fs-TAS

飛秒瞬態吸收/拉曼光譜儀fs-TAS

直接聯系

天津東方科捷科技有限公司

美國

產品規格型號
參考報價:

面議

關注度:

1051

產品介紹

Transient Absorption Spectrometer (TAS)

可以同時獲取:飛秒瞬態吸收時間分辨光譜;飛秒瞬態拉曼光譜;

Our Transient Absorption Spectrometer (TAS) is a state-of-the-art instrument for femtosecond pump-probe spectroscopy. In an ultrafast time resolved experiment using TAS, a sample of interest is excited by an electronically resonant coherent femtosecond pulse referred to as the “pump.” This causes changes to the spectrum of the sample, which are monitored as a function of time by the white light supercontinuum probe, as sensed by the combination of a spectrograph and a camera or photodiode array.

  • Flexibly designed femtosecond pump-probe spectrometer

  • Supports a variety of ultrafast amplifiers & optical parametric amplifiers as input

  • Broad pump-probe delay range and high pump-probe delay resolution

  • Flexible imaging spectrograph supports automated switching of spectral range (detector) and resolution

  • Robust, stable device is factory assembled and aligned for easy integration

  • Worldwide installation and support is available

  • Many samples require a pump with wavelength different from that of the fundamental wavelength of the ultrafast laser. For this reason, TAS is often sold with an external optical parametric amplifier or harmonics generator. TAS is also offered with an addition of an internal second harmonic generation (SHG) option for the pump beam. The energy of the pump beam can be controlled internally by using a variable reflective neutral density filter imprinted on a thin glass substrate. This reduces the GVD introduced to the beam while allowing power control over a range of 0-4 OD. In order to reduce the effect of laser fluctuations, a TAS measurement is most typically performed at half the repetition rate of the laser using a New Focus phase locked optical chopper to block every other pump pulse. The spectrum of the transmitted or reflected white light supercontinuum probe is compared to the spectrum when the pump is present at half the repetition rate of the laser, the fastest rate possible, in order to minimize the effect of any laser noise and fluctuations on the end measurement.

The standard maximum optical delay between pump and probe in TAS is 3.3 ns. This is limited by the length of the stage (250 mm) and the number of optical passes that the probe beam makes to and from the high quality retroreflector used on the stage. In standard configurations, there are four passes (to and from the retroreflector twice). The resolution changes depending on the mode of operation. In the best case, the resolution is set by the minimal incremental motion (MIM) of the delay stage. This is applicable when performing a single measurement where the stage is incremented linearly in only one direction. In the standard TAS configuration, this is 13.3 fs. If many scans are to be averaged, the repeatability of positioning must be considered. If performing the same measurement, the uni-directional repeatability must be accounted for, which is also 13.3 fs in the standard TAS configuration. Lastly, if the set of time points is acquired randomly, as is often the case to minimize the effect of laser and sample changes to the measured dynamics, the bi-directional repeatability is the most important factor. For the standard TAS, this has a value of 26.6 fs. While the standard specifications are more than sufficient for most experiments, upgrades are available to increase the maximum optical delay and to reduce the minimum step size. The simplest, and most cost effective, upgrade is achieved by simply adding an additional retroreflector to the delay stage. There are then eight passes (to and from both reflectors twice) and the optical delay is increased to 6.67 ns. The unfortunate disadvantage of this configuration is that the resolution is also reduced by a factor of 2. For example, the MIM becomes 26.6 fs and the bidirectional repeatability becomes 53.2 fs, which is insufficient for some laser systems. To combat the resolution limits, it is possible to replace the linear stage and motion controller from the standard TAS configuration. With the ILS250HA stage and 2 retroreflectors, the optical delay is 6.67 ns, the MIM is 8 fs and the bidirectional repeatability is 18.6 fs. Alternatively, for the very best performance, the ILS300LM stage can be used with Newport’s XPS motion controller. This allows for optical delay up to 8 ns, MIM of 0.26 fs, and bidirectional repeatability of 8 fs. Additionally, the stage can move at up to 5 times higher speed than the standard TAS model and therefore random scans do not take as much time to perform.

產品咨詢

飛秒瞬態吸收/拉曼光譜儀fs-TAS

天津東方科捷科技有限公司

請填寫您的姓名:*

請填寫您的電話:*

請填寫您的郵箱:*

請填寫您的單位/公司名稱:*

請提出您的問題:*

您需要的服務:

發送

中國粉體網保護您的隱私權:請參閱 我們的保密政策 來了解您數據的處理以及您這方面享有的權利。 您繼續訪問我們的網站,表明您接受 我們的使用條款

飛秒瞬態吸收/拉曼光譜儀fs-TAS - 1051
天津東方科捷科技有限公司 的其他產品

FLOW

光譜檢測分析儀
相關搜索
關于我們
聯系我們
成為參展商

© 2025 版權所有 - 京ICP證050428號

主站蜘蛛池模板: 四虎影院免费观看视频 | 手机看片1204国内基地在线 | 欧美亚洲自拍偷拍 | 99热这里只有精品在线播放 | 日本特交大片免费观看 | 国产第一福利精品导航 | 欧美日韩视频二区三区 | 久免费视频 | 免费lulu网站 | 黑人在线 | 四虎在线网址入口2022 | 国产精品欧美视频另类专区 | 久久夜夜视频 | 亚洲国产高清视频 | 午夜手机视频 | 国产特黄a级在线视频 | 两个人免费观看高清视频图 | 日本精品中文字幕在线不卡 | 热99精品在线 | 精品福利在线观看 | 久久精品国产精品亚洲婷婷 | 青青热久免费精品视频网站 | 六月丁香色婷婷 | 国产成人久久精品二区三区牛 | 国产区精品 | 欧美性视频xxxxhd | 国产精品亚洲精品爽爽 | 欧美激情一区二区三区视频 | 91精品啪在线观看国产色 | 久久精品国产一区二区三区 | 蜜桃精品视频 | 日韩在线视频免费 | 四虎成人免费 | 欧美三级网站 | 国产4tube在线播放 | 日本黄色高清网站 | 丁香六月婷婷综合激情动漫 | 69热精品视频在线看影院 | 香蕉成人 | 亚洲欧洲另类 | 毛片大片免费看 |