粉體行業在線展覽
面議
537
Features
Closed flow system provides clean conditions and exclusion of air
Staining procedures are reliable and reproducible
Exposure to staining solutions is minimized
Extremely low operation costs
Individual staining procedures may be easily configured
Simple maintenance due to freely accessible tubing and valves
The Need
Since most organic materials produce only low-contrast results in transmission electron microscopy (TEM), staining procedures are needed to increase the image contrast.
Staining involves treatment with solutions that contain heavy metal salts (e.g. uranium, lead, osmium or tungsten), which attach to certain cellular components (peptides, lipids, nucleic acids etc.). These salts contain ions with a high number of protons. When the electron beam passes through a sample area decorated with such ions, it increases image contrast.
Problems With Manual Staining
All TEM preparation procedures require very clean conditions, as even minor contaminations are visible in the high magnifications of the TEM.
Lead citrate solutions are very sensitive to exposure to carbon dioxide, because this results in a precipitation of fine particles of lead carbonate, which instantly damages the sample. Therefore, the staining process must exclude atmospheric air.
In many labs, TEM staining is accomplished by hand. The grids are placed on small drops of staining solutions and washed between and after staining steps. It is very difficult to avoid contamination. Many samples are discarded.
Processing grids by hand is also very time consuming, and the number of grids that can be stained simultaneously is limited. Furthermore, manual staining increases the risk of exposing the user to potentially harmful substances.
Solution: QG-3100
The QG-3100 automatic stainer increases both the staining quality and the yield by minimizing contamination, while saving time and reducing waste.
Through the unit’s unique design, which uses a peristaltic pump and pinch valves, the solutions are isolated to the tubing and grid chamber. Liquids flow in only one direction. In addition to minimizing contamination, this design significantly reduces the time and waste associated with other techniques.
Open, Flexible Design
All components exposed to the staining solutions are easy to replace. Maintenance is simple and may be performed by the user. Extra input and output channels, freely programmable routines and an exchangeable grid chamber allows the realization of various laboratory tasks (e.g. graded ethanol series).
Supplied complete with the following:
Main staining unit complete with peristaltic pump control valves, large illuminated touch screen controller/monitor, quick release processing chamber with grid loading plate
Grid loading/unloading tools
Cleaning holder
Filling syringe with weighted dispenser
Waste storage bottles with rack
Interconnect tubing
Drip tray
Power cord
Instruction manual
Specifications
Gross shipping dimensions: 80cms x 60cms x 60cms
Shipping Weight: 45 kg